Hello, i need value for tr2 transformer voltage secundary ? Amp? I sopose prim 230V secundary 2x15V 10VA
its correct? Please help. Best regards.
Comments
Hello, i need value for tr2 transformer voltage secundary ? Amp? I sopose prim 230V secundary 2x15V 10VA
its correct? Please help. Best regards.
Hello:
https://elektrotanya.com/awelco_micro_AWM5680-AA_sch.pdf/download.html
Bálint
0
I have this schematic s but TR2 dont show value, i need replace tr2 i thing is 2x15 v 1A ?
0
https://www.matei.ro/emil/awelco_mikro_164.php
0
File Not found
0
0
Fixed the link. Try now!
0
Ok, good, but its the same, value for the TR2 ? Not specificates.
0
I measured the following idle data:
Upr: 238V
Usec-1:19,38V
Usec-2:19,38V
Transformer sizes:
40x34 mm packet thickness:15 mm
core: 2,25 cm2
power approx. 5-6VA