Hello,
recently bought this lens as "broken/for parts" item. After inspection found there is missing FPC cable, bought one from Aliexpess. Installed it, still not working. After long searching in google was able to find a repair video, that there is seen for a while that there is something with 2-wires in the slot, that is in the photos.
Here is video at the moment that the part can be seen: https://youtu.be/PjEBGFLjgM0?t=410 (from about 6:50 mins). At 10:44 is seen that the part is only in the bottom side of the slot; and nothing more detailed in the whole internet that I was able to check for about a hour.
There is magnetic field sensor - top left on the DSC07181 and on the next photo fitted on its place, so I think it should be some kind of tiny end position switch or don't know what;
any help as service manual, photo or part number will be in help.
Regards,
Milen
Hi friends,
I would like to make adjustments to my Sony DSC-F717.
According to service manual, the service remote is attached via CPC jig, where a 2,5mm LANC port is mounted. I'd like to DIY a improvised jig.
Exact detail of the jig is not provided, but clearly it is a 22-pin FPC splited into many measure points and a LANC port. Also learned from the manual that LANC signal to/from CPC is splited into 2 lanes, IN and OUT, while 2,5mm LANC port only has 1 (bidirectional) data bus. I wonder if these 2 signals are mixed by additional circuits on the jig.
If someone can post a back (trace-side) photo of CPC12, the mystery will be solved and it will be much appreciated, thanks in advance!
Hello everybody,
Sony CCD TRV-238E camcorder has two issues, first, a wire in the harness( PD-124) is almost cut, which causes bad contact in the LCD panel, I've tried to used a sort of glue to fix it but without success, soldering the two parts is almost impossible ( see picture), the area is too tight.
Second, when the connexion for standard flexible are cut it is possible to scratch the two parts and connect them with extension wire and welding, but in the case of the CONTROL KEY BLOCK's flexible which is used to connect the CONTROL KEY BLOCK to the mainboard, connexions are not made of copper! (carbon maybe, trying to polish will destroy them!), actually, they are worn out (see picture).
Because these spare parts are no longer available in my country, please I need your advice to fix harness and CONTROL KEY BLOCK's flexible.
Sziasztok!
C32:30 és C31:30 hibakódot jelez a kamera. A kazettát nehezen veszi be,/resetelni kell/ bevétel után pörgeti balra aztán jobbra próbálná, de csak hang van fizikailag nem teker ekkor adja a C32.30 hibakódod. A kazetta ajtó kapcsolója eltörött azt helyettesítettem egy nyomógombbal ideiglenesen.
Üdv.