Service manuals, schematics, eproms for electrical technicians

LG 1 24C02 14V8 3600MAH LI-ION

OTHER - EPROM
Type: (E2P)
Size
408.0byte
Page
---
Category
OTHER
EPROM
If you get stuck in repairing a defective appliance download this repair information for help. See below.
Good luck to the repair!

Please do not offer the downloaded file for sell only use it for personal usage!

Looking for similar lg manual?
Document preview [1st page]
No preview item


No preview item for this file.

Possible causes:
  • No preview picture generated yet.
  • It is not a pdf file.
Advertisements
Please tick the box below to get download link:
  • Also known:
    LG LIION 24C02 14V8 3600MAH 24 02 14 3600 MAH LI ION LI-ION
  • If you have any question about repairing write your question to the Message board. For this no need registration.
  • If the site has helped you and you also want to help others, please Upload a manual, circuit diagram or eeprom that is not yet available on the site.
    Have a nice Day!
  • See related repair forum topics below. May be help you to repair.
Warning!
If you are not familiar with electronics, do not attempt to repair!
You could suffer a fatal electrical shock! Instead, contact your nearest service center!

Note! To open downloaded files you need acrobat reader or similar pdf reader program. In addition, some files are archived,
so you need WinZip or WinRar to open that files. Also some files are djvu so you need djvu viewer to open them.
These free programs can be found on this page: needed progs
If you use opera you have to disable opera turbo function to download file!
If you cannot download this file, try it with CHROME or FIREFOX browser.
Translate this page:
Relevant OTHER forum topics:
reloop rmx40usb keverőpult 2-3 óra üzem után torz a hang a fejhallgatón
Tisztelt szakik! A címben említve a lényeg! Elöljáróban: a készülék korábban valami löttyel le lett öntve(kikapcsolt állapotban) próba után a master ledkijelző csinált hülyeségeket, de kontaktspré folyatásával a lötyimaradék a látható/vélhető aláfolyt helyekről le lett pucolva- kijelző bibi megszünt. továbbá a fejhallgatóból több is ki lett próbálva és másiknál is csinálja, a hangerejét lehet szabályozni de halkan-hangosan is torz. a készülék várhatóan jövőhét végén kerül hozzám, addig én ennyit tudok!A kapcsrajz itt a honlapon megvan, töltöm és átnyálazom! Vélemény?
LG S12AM kültéri vezérlés
Üdv Mindenkinek!
Évek óta működő LG S12AM kültéri (ASUW1264GG1) túláram miatt lekapcsolja a kismegszakítót. Kezdetben még egy-egy ilyen eset után vissza lehetett kapcsolni a kismegszakítót és ment tovább a klíma. Most már fixen nem megy.
Minden csatlakozást lehúztam (ventillátor, kompresszor, 4 utas szelep, stb), terhelés nincs, csak a 230AC betáp, de továbbra sem megy. Égésnyom nem látszik. Feszültségeket nem tudok mérni ebből adódóan. Kondenzátorok nem púposak. Hogyan tovább?
Fejhallgató - törött műanyag vezetősín
Üdv! A csatolt képen látható fejhallgató szárvezetője széttörött. Hogyan lehetne ezt jól megjavítani? A torott_burkolat.jpg-n látható a feladat. Amik eszembe jutottak, mint lehetséges megoldások: - ALU ragszalaggal körbetekerni, ha nem nyúlik a szalag - vékony drótot körben beleolvasztani a műanyagba. Plomba drót lenne szerintem a legjobb a bordázottsága miatt. - szögletes acélgyűrűt ráhúzni Pillanatragasztót, epoxit elvetettem, szerintem hosszabb távon széttörnének. Ami a nehézséget adja: olyan NDK-s megoldást valósítottak meg, hogy a latkep.jpg-n piros nyillal jelölt csavarfej kapaszkodik bele a nyíl végén látható fülbe. Kb 0.5-1 milliméter műanyag tágulás esetén a csavar feje kiugrik a kapaszkodó fülből és annyi. Ehhez hasonló "ötletességgel" a Wartburg ajtónyitó mechanizmusában találkoztam, de az nem prémium termék volt. Bármi ötletet örömmel veszek! Update: újabb képek, tores_reszletes1,2
LG PF1000U Ultra Short Throw Projector (chassis FM51E) Firmware
Good afternoon!

I'm looking for a dump for the LG PF1000U projector (chassis FM51E), (NAND Hynix H27U1G8F2CTR SPI_FLASH: MX25L8035EM2I, EPROM 24C256C).

There is no epk file available anywhere :( 

This device attempts to turn on and responds to both buttons and the remote control:

It exits standby, runs the fans for 5 seconds, then spins them at 100% for another 5 seconds judging by the sound, and then goes back into standby.

The problem seems to be a corrupted NAND as it appears to me:

[ 0.110000] NAND device: Manufacturer ID: 0xad, Chip ID: 0xf1 (Hynix NAND 128MiB 3.3V 8-bit)
[ 0.110000] redirect_size = 400000, redirect_start = 7c00000
[ 0.110000] Loading nand bad block info(00000000+00020000)...
[ 0.119000] Mstar nand-flash partition definition
[ 0.119000] mtd info: # of partitions = 23
[ 0.119000] Creating 23 MTD partitions on "NAND 128MiB 3.3V 8-bit":
[ 0.119000] 0x00000000-0x00020000: "bbminfo"
[ 0.120000] 0x00040000-0x00060000: "mtdinfo"
[ 0.121000] 0x00160000-0x00760000: "rootfs"
[ 0.121000] 0x00760000-0x007c0000: "lginit"
[ 0.122000] 0x007c0000-0x007e0000: "crc32info"
[ 0.123000] 0x007e0000-0x00800000: "model"
[ 0.124000] 0x00800000-0x00900000: "logo"
[ 0.124000] 0x00900000-0x00a00000: "cmndata"
[ 0.125000] 0x00a00000-0x01200000: "nvram"
[ 0.126000] 0x01200000-0x01300000: "user"
[ 0.127000] 0x01300000-0x01400000: "ezcal"
[ 0.128000] 0x01400000-0x014a0000: "estream"
[ 0.128000] 0x014a0000-0x01620000: "opsrclib"
[ 0.129000] 0x01620000-0x018a0000: "kernel"
[ 0.130000] 0x018a0000-0x03560000: "lgapp"
[ 0.131000] 0x03560000-0x04fa0000: "lgres"
[ 0.132000] 0x04fa0000-0x05be0000: "lgfont"
[ 0.132000] 0x05be0000-0x05c00000: "tplist"
[ 0.133000] 0x05c00000-0x07640000: "lgres"
[ 0.134000] 0x00080000-0x000a0000: "cert"
[ 0.135000] 0x000a0000-0x00140000: "authcxt"
[ 0.136000] 0x00060000-0x00080000: "hdcp2"
[ 0.137000] 0x00140000-0x00160000: "keyrsrv"
[ 0.138000] mod_nand_init is invoked
[ 0.138000] GE driver inits
[ 0.138000] mod_iic_init is invoked
[ 0.138000] model option = 0xfc
[ 0.138000] Mstar_emac: [PHY Addr] ==> :0
[ 0.138000] Mstar_emac: alloRAM_VA_BASE = 0xA0C40000 alloRAM_PA_BASE= 0xC40000 alloRAM_SIZE= 0x100000
[ 0.139000] RBQP_BASE = c44000
[ 0.140000] [SCALER][000173] _mod_scaler_init
[ 0.140000] [TTX_DRV][00508]init 170
[ 0.140000] MDrv_CC_Init
[ 0.140000] init 172
[ 0.140000] [DEMOD_DRV][00369]init 245
[ 0.140000] [BDMA_DRV][00629]init 251
[ 0.141000] TCP cubic registered
[ 0.141000] NET: Registered protocol family 17
[ 0.142000] RPC: Registered udp transport module.
[ 0.142000] RPC: Registered tcp transport module.
[ 0.142000] Adding user_initcall[0] = 0x803a1314
[ 0.142000] Adding user_initcall[1] = 0x803a1320
[ 0.142000] Adding user_initcall[2] = 0x803a66f8
[ 0.144000] VFS: Mounted root (squashfs filesystem) readonly.
[ 0.150000] VFS: Mounted lginit (squashfs filesystem) readonly.
[ 0.150000] Freeing unused kernel memory: 132k freed
[ 0.204000] SQUASHFS error: Can't find a SQUASHFS superblock on mtdblock19
[ 0.225000] Empty flash at 0x000213bc ends at 0x00021800
[ 0.234000] Empty flash at 0x00023200 ends at 0x00023800
[ 0.242000] Empty flash at 0x00024bbc ends at 0x00025000
[ 0.250000] Empty flash at 0x000271ec ends at 0x00027800
[ 0.250000] jffs2_scan_inode_node(): CRC failed on node at 0x00028fe0: Read 0xffffffff, calculated 0x916f9a2e
[ 0.258000] Empty flash at 0x00029120 ends at 0x00029800
[ 0.264000] Empty flash at 0x0002ab84 ends at 0x0002b000
[ 0.289000] Empty flash at 0x00040878 ends at 0x00041000
[ 0.289000] jffs2_scan_dirent_node(): Node CRC failed on node at 0x000427f4: Read 0xffffffff, calculated 0x2322e93d

Thank you in advance!
Similar manuals:
If you want to join us and get repairing help please sign in or sign up by completing a simple electrical test
or write your question to the Message board without registration.
You can write in English language into the forum (not only in Hungarian)!

E-Waste Reduce