Screenshots of problem here in the post.
Picture of screen with both cables to panel from TCON connected, and the other is with one side disconnected.
I have read the cables from the TCON to the display loosen up on the end to the panel. I believe as I am working on moving the cables around, the picture is improving
and getting clearer. So I think thats the problem. Someone mentioned using tape over them to hold them to the panel better. I have not taken the metal frame off to
look at them, but there is a narrow gap where I read some people stuff cardboard in there to press down on them better.
Has anyone ever seen this issue and come up with a good way to resecure the cables?
Üdv mindenkinek!
A fent nevezet készüléknek (SONY KV21T1K)-ha tudjátok a(+B) (sortápjának) a feszültségét,mert a kapcsolási rajzban a rendszer táp,(sortáp) 118V van meg adva de nálam terhelt állapotban 136V van hozzá teszem hogy a többi feszültség az a meg adott érték.
Várom a megtisztelő válaszotokat.
Üdvözlettel:buszosgyuri
Üdv Kollégák!
Fenti TV-ben a Q6803 pozícióban lévő sorvég tranyó zárlatos.Típusa 2SC5480,ez a két végtanyó közül a felső pozícióban van.Ára meglehetősen drága,a HQ-ban több mint 4000Ft.Korábban a Tanyán találkoztam olyan javaslattal,hogy helyettesíthető 2SC5480-al.Nos én megpróbáltam,de egy ciccenés után elszállt.Előtte természetesen sor kondikat cseréltem,tápot egyébként is javítani kellett.Most vakarom a fejem,vegyek bele eredetit,vagy legalább próba szinten elindul mással is?Kérek tanácsot,ha már volt hasonlóval dolgotok!Köszönettel
Reparátor1
Üdv Mesterek!
Hozzám került egy fenti típusú készülék, ami azt produkálja, hogy bekapcsolás után leáll és a LED 2 villanással figyelmeztet, hogy valami túláram van a B+ áramkörében. Én a hibakódok alapján ezt olvastam ki.
A bekapcsoláskor megjelenik a B+ rendesen és úgy 1-2 másodpercre indul a gép, majd leáll! A sorvégfoknál minden jónak tűnik. Akkor mi a baja a B+-al?
Mi lehet még a hiba oka?