I have and found most of the voltages as indicated on the circuit diagram, till op amp M 5218P; are near those specifed. The output on the centre of the two power transistors of both the channels are also alright.
While looking at the voltages on test points as mentioned on the page 7 for setting up quiscent current, these cannot be set.
Bit of history, the amplifier was lying unused for long time. Nothing in it has burnt. It was never opened earlier than this time, couple of days back.
While I was probing for voltages with DMM, with probe on collector of TR413 one of the fuses blew up. Later same thing happened on the other channel as well.
With the above as background can a Good Samaritan figure out feasibility of repair.
i am unable to upload service manual as file size is 7.3 mb
Sziasztok. A címben szereplő erősítővel van egy kis gondom és segítséget kérnék tölletek.
Két ellenállás megégett benne és nem tudom az értéküket. Rajzom van az erősítőhöz de sajnos nem lehet leolvasni róla az értéket. R761 és R762 ellenállásokról van szó gyanitom hogy egyformák.
A másik kérdésem az lenne hogy C4558C ic-t mivel tudnám kiváltani. Köszönöm
Sziasztok!Hozzám került javitásra egy pár HS 288-as 8Ohm-os hangfalpár.Egyikbe magas másikba közép pille csere.(szakadtak voltak)A középsugárzókon lecseréltem az 1984-es 4.7Mf-os elkót,bipolárisra ahogy azt kell.Abban kérnék Tőletek segitséget,hogy miért van az,hogy az egyik hangfalban forditva van bekötve a középnyomó a másikban meg nem.Mi a magyarázata ennek?És ráadásul ezt már a második esetben tapasztalom meg.Ugyanez volt nem rég egy HS 282-ben is.Nem értem.Segitségeteket előre is köszönöm!
BRG M20 hangerő szabályozó erősen kontakthibás.
Az eredeti 10kC + 25kA kettős poti beszerezhetetlen. (elfekvőben valakinél??)
A szabályozás az első és második erősítő tranzisztor között, az első tranzisztor visszacsatolását állítja.
Kérdés: 10kB potival hogyan lehetne korrekten megoldani a javítást?