elektrotanya.com - service forum & info
Service manuals, schematics, eproms for electrical technicians

Thank You!
TEKTRONIX 2445A 2455A SM
METER - SERVICE MANUAL
Type: (PDF)
Size
85.0 MB
Page
330
Category
METER
SERVICE MANUAL
Sponsored link
Warning!
If you are not familiar with electronics, do not attempt to repair!
Whether you suffer fatal electrical shock! Instead, contact the nearest service center!


Please, do not make a copy of the downloaded manual and do not offer to sell it,
just use personally to repair defective appliance! Good luck to the repair!

Looking for other manual?
Document preview
TEKTRONIX 2445A 2455A SM service manual (1st page)
Preview of TEKTRONIX 2445A 2455A SM [1st page]
Click on the link for free download!
Sponsored link
This file is downloadable free of charge: ...processing...
Note! To open downloaded files you need acrobat reader or similar pdf reader program. In addition, some files are archived,
so you need WinZip or WinRar to open that files. Also some files are djvu so you need djvu viewer to open them.
These free programs can be found on this page: needed progs
If you use opera you have to disable opera turbo function to download file!
If you cannot download this file, try it with CHROME or FIREFOX browser.
Sponsored link
Translate this page:
Relevant forum topics:


Tektronix DC502 option 1
Hello. This is my first post on the forum. I have a defective meter Tektronix DC502 Frequency Option1. SM fits the DC501. The damage is that it always displays "1111111". Generator 5MHz is operational. 7490 dividers as well. Unless the system is damaged 74LS112 U165. On its output there does not appear, regardless of whether the generator is working or push reset. Can anyone confirm this? Sorry for my English, I use google translate.
Tektronix 2215 oszcilloszkóp, a két csatorna összegzése esetén 1 cm ofszet hiba keletkezik. Miért?
Sziasztok! A fenti szkóp beállítása a leírásnak megfelelően megtörtént. A két csatorna bemenete GND-re kapcsolva. Mindkét sugarat pontosan középre állítva, ha összegzem a két jelet (Both & ADD) beállításban a sugár közel 1 centit lefelé mozdul. Nem találtam erre vonatkozó beállítást. ALT és CHOP módban a két vonal pontosan fedi egymást (jel esetén is). A két csatorna erősítése is egyforma (külön mérve). Az CH2 jele invertálható, de azt is beállítottam úgy, hogy az INV ki-be kapcsolásakor a sugár nem mozdul el középről. A rajz alapján diódamátrixokkal kapcsolgatja a csatornákat, csak az nem világos, hogy ha mindkettő külön- külön DC-ben középen van, akkor összeadva miért mozdul el a sugár? Üdv.
Tektronix 2225 oscilloscope a képernyő bal oldalán erős világító pont látható Megoldva
Sziasztok Tek. 2225 scopon a képen látható hiba javításához kérnék segítséget. SM letöltve, all tápfesz megfelelő. A fénypontot el tudom mozdítaani a hor.pozition gombbal.A scope múködik, senki nem matatott benne. Müködö oscilloscopom van. Nem tudom, hogy a képek átmennek-e Köszönettel Gyuri
Tektronix 442 oszcilloszkop javitas
Sziasztok. Erossen szuksegem volna egy oszcilloszkopra, mar 2 erosito is van nalam, ami varja a muszert. A baj az, hogy igencsak szukos keret van e celra. Kineztem egy Tektronix 442 tipust, az elado szerint nincs eletjel benne, meg az elolapon levo "power" led sem vilagit. Erdemes lenne ezt megvennem?
Tektronix 7633 readout repair
I have a problem with the Tektronix 7633rd Readout is not working. Displays only the spot, (no time base on the screen), from time to time, jump to the next position where it should be readout. After adjustment knob charcter scan, there's a readout, but the characters were, or blurred, or not drawn to the end - in pieces, imposed on themselves. The readout is off everything works. For all kinds of advice I would be very grateful.
Tektronix t912 szkóp javításhoz segítséget keresek (a memória nem működik)
Tekteonix T912 szkópom kontakthibás lett , úgy hogy eltűnt az X sugár .Ha megkoccintottam a dobozt visszajött és hetekig nem jelentkezett.Mígnem 1X ugyanez játszódott le és azóta nem akar a memória működni.Természetesen szétszedtem és megtaláltam a kontakthibát ,amely nem cinezés , vagy repedés volt , hanem a táp panelon a testet , kettő csavaranya vitte át a fémházra,és ez okozta az említett hibajelenséget.Egy következő alkalomkor fel fogom tölteni a javításnak ezt a részét.Most ami a bánatom , hogy a cső memóriája nem működik , annak ellenére hogy a feszültségek , és a jelalakok megegyeznek a sémán levő adatokkal. megkérem ,aki jártas e területen vigasztaljon meg engem, ha a test szakadozása végett esetleg túlfeszültség juthatott a cső ezen pontjaira , már mint a tároló részére , attól tartósan károsodhatott a katódsugárcső?Megjegyzem , mint szkóp , tökéletesen működik,és ha van remény hogy foglalkozzak a javítással tovább akkor ha eredmény születik feltöltöm , elejétől végéig a tapasztalatokat.Mellékelem a séma azon oldalait amelyek végzik az analóg tárolást.Köszönet a segítőknek "(olyan fórum téma megnevezést/elnevezést válassz, ami beszédes, minél pontosabban illeszkedik arra, amivel kapcsolatban írsz. pl: ORION LCD PT26S chassis 17MB12-2 nem indul ) Az pl. nem elég, hogy "LG RE" vagy "Cuccok!!!" és így tovább... Comprende!?" A címet igazítsd ki légy szíves. Kalex