You are here

Kenwood CS-1021 oscolloscope difficulty in adjusting track

3 posts / 0 new
Last post
Tiziano958
Tiziano958 picture

Hello everyone.
I can't use all of the track settings on my CS-1021 oscilloscope.
"Astig" must be turned fully clockwise, "Intensity" does not work, "Focus" must be turned fully clockwise, "Trace Rotation" is the only command that works.
What can I check?
Thank you

Comments
Kari
Kari picture
*****

Hi,
I think you must check the Focus-voltage attenuator/latter, but be carefull pleaase and use a HV-Probe!
(its High Ohmic part)...
Kari

0

Tiziano958
Tiziano958 picture

Thanks, i will do this check
 

0