Micky86 picture

Good evening, problems on Solomon SL20? the "Power" light comes on, as well as Heater, but nothing else? the rotation of the pot. temperature, only causes Heater to switch off or tremble, does the iron heat up?

Comments
Joe
Joe picture

Hi!

Te schematic is this https://elektrotanya.com/solomon_sl-20_sch.pdf/download.html, except the display. 

Do you measured the soldering iron? The heating coil should be...

0

SzBálint
SzBálint picture
****

hello: a WD40 nem alkalmas elektronikához
Kontakt 61 kell

Bálint

0

SzBálint
SzBálint picture
****

0

Micky86
Micky86 picture

Thanks for the link, I already looked before asking the question? but I don't understand what is happening? what should I check? 

0

torokj
torokj picture

Hello Mickey,
Check the resistance of the heater (cca 15 Ohm),and measure voltage at thermo (cca 1mV / Celsius.) Probably the thermo is broken.If you short the thermo,does the heating start?
Good luck to repair!
TJ

0

SzBálint
SzBálint picture
****

hello:

0

Micky86
Micky86 picture

Hello, and thank you for your answers, the iron heats up, but the rotation of the pot. injected (to clean) WD 40 into the pot. and was not special contact ??on the other hand have noticed, that before this intervention?
the pot.a bottom are the last red LEDs on the right did not light up? can be normal? I will follow the advice and do the measurements on the iron. Have a nice day

0

Micky86
Micky86 picture

after several tests this morning, I see? what if I remove the Din plug? sttion powered, the LED bar works? I keep looking, any ideas are welcome.
Would it bother me not to be able to put it back into service? gift from a DCD friend...

0

torokj
torokj picture

Hello,
Measure voltage at pin 13 of the opamp DA1.4 This is the control voltage from the temperature controller potmeter.Normally its  between 0.1-0.5 V,depends on the preset temperature.After measure voltage at output pin 08 of the opamp DA1.3. Its the amplified voltage from the thermo.Without heating its cca 0-0.1 V.If the heating starts,the voltage goes up to 0.3-0.4 V until the temperature reaches the desired value,the output pin 14 goes low,the heating stops. Probably you should change the heating element.
TJ

1

Micky86
Micky86 picture

smiley 
Good morning, Thanks for the reply, Oui if I understood correctly? I have to find a tension between the 2 wires of the Thermo couple? station in operation? sorry, but not used to this kind of components, actually I am considering replacing the iron, but after having checked everything. I did another test yesterday, there is still only the "Heater" light which is controlled by the pot.Central? when the last 4 "red" view that no registration from the temperature setting, towards this? wonder if are functional? Good weekend

0

torokj
torokj picture

Hello
I' ve measured the voltage at the thermo.
400 °C 27 mV,300 °C 20,6 mV,200 °C 12 mV,150 °C 9,2mV.At room temperature almost zero. (cca 6,5-7 mV/ 100 °C) 
Good luck to repair.
Bonne chance
TJ

0

Micky86
Micky86 picture

triste OK, thank you very much for this information, are these measurements in AC, or DC? CCA (alternative?) for 6.5/7 mv at 100° thank you in advance. have a nice weekend

0

torokj
torokj picture

Of course DC.Its a thermocouple.

0

Micky86
Micky86 picture

Hello, I come back to the site? because still not solved my Solomon SL 20 station problem the iron heats up, but impossible, even by manipulating the potntiometer? to turn on the led bar? except by unplugging the iron from its socket? if anyone has a solution? I follow taker ,in advance thank you.

0

ityvity
ityvity picture
*

If I understand correctly, it heats up, but it is not possible to regulate the temperature, the LED stays on ful  all the time. Thermal element error, or the wire is broken.

0

Micky86
Micky86 picture

Thank you for the answer, yes that's it, the iron heats up, but no LED on the bar lights up? except that of voltage presence, I also noticed that following the change of the breakdown? the new one had play, diameter slightly different from the old one? can this influence the operation of the thermocouple?

0

Sponsored links