AWELCO base 5680 transformer value

Hello,  i need value for tr2 transformer voltage secundary ? Amp? I sopose prim 230V secundary 2x15V 10VA   
its correct? Please help. Best regards.

Comments
SzBálint
SzBálint picture
****

0

Boss
Boss picture

I have this schematic s but TR2 dont show value, i need replace tr2  i thing is 2x15 v 1A ?

0

mpisti
mpisti picture

0

Boss
Boss picture

File Not found 

0

mpisti
mpisti picture
This is a drawing of the power supply.

0

pihe
pihe picture
*****

Fixed the link. Try now!

0

Boss
Boss picture

Ok, good, but its the same, value for the TR2 ? Not specificates.

0

mpisti
mpisti picture

I measured the following idle data:
Upr: 238V
Usec-1:19,38V
Usec-2:19,38V

The measurement was performed with a desoldered transformer.
Transformer sizes:
40x34 mm packet thickness:15 mm
core: 2,25 cm2
power approx. 5-6VA
 

0