TEKTRONIX 2445 SZKOP

METER - SERVICE MANUAL
Type: (ZIP)
Size
28.7 MB
Page
---
Category
METER
SERVICE MANUAL
If you get stuck in repairing a defective appliance download this repair information for help. See below.
Good luck to the repair!

Please do not offer the downloaded file for sell only use it for personal usage!

Looking for similar tektronix manual?
Document preview [1st page]
No preview item


No preview item for this file.

Possible causes:
  • No preview picture generated yet.
  • It is not a pdf file.
Advertisements
Please tick the box below to get download link:
  • Also known:
    TEKTRONIX 2445 SZKOP
  • If you have any question about repairing write your question to the Message board. For this no need registration.
  • If the site has helped you and you also want to help others, please Upload a manual, circuit diagram or eeprom that is not yet available on the site.
    Have a nice Day!
  • See related repair forum topics below. May be help you to repair.
Warning!
If you are not familiar with electronics, do not attempt to repair!
You could suffer a fatal electrical shock! Instead, contact your nearest service center!

Note! To open downloaded files you need acrobat reader or similar pdf reader program. In addition, some files are archived,
so you need WinZip or WinRar to open that files. Also some files are djvu so you need djvu viewer to open them.
These free programs can be found on this page: needed progs
If you use opera you have to disable opera turbo function to download file!
If you cannot download this file, try it with CHROME or FIREFOX browser.
Translate this page:
Relevant METER forum topics:
Tektronix 7633 readout repair
I have a problem with the Tektronix 7633rd Readout is not working. Displays only the spot, (no time base on the screen), from time to time, jump to the next position where it should be readout. After adjustment knob charcter scan, there's a readout, but the characters were, or blurred, or not drawn to the end - in pieces, imposed on themselves. The readout is off everything works. For all kinds of advice I would be very grateful.
Tektronix DC502 option 1
Hello. This is my first post on the forum. I have a defective meter Tektronix DC502 Frequency Option1. SM fits the DC501. The damage is that it always displays "1111111". Generator 5MHz is operational. 7490 dividers as well. Unless the system is damaged 74LS112 U165. On its output there does not appear, regardless of whether the generator is working or push reset. Can anyone confirm this? Sorry for my English, I use google translate.
Tektronix 314 oszcilloszkóp-kettős potenciométer tengelye hiányzik
Sziasztok! Egy Tektronix 314 szkóp kettős potenciométereinek az egyik tengelye hiányzik!Konkrétan csak egy olyan van ahol korrektül látszik a két egymásban futó tengely. A többinél csak elpörög a tekerő és ha leszerelem csak egy tengely látszik! Mellékelek képeket is! Kérdésem az lenne, hogy hogyan lehet esetleg ezeket a potmétereket javítani, mert amúgy hibátlan a szkóp! Köszönöm!
Tektronix oszcilloszkóp mi a hibája
Sziasztok!  Találkozott már valaki ilyen problémával, a szkóp képcső képén kerek foltok vannak. Képcső foszfor kiégésre gondolok, de lehet hogy hibás az elképzelésem. Várom az javaslatokat, mi a hiba. Felélesztettem egy Tektronixot és ezt produkálta.