Hi.
SORRY for my bad english.
My problem is that the waveform is not stay fixed in the oscilloscope, even with the LEVEL volume changing.
Does anyone know which part of the oscilloscope the problem is from?
Regards Nb.
Comments
Hi.
SORRY for my bad english.
My problem is that the waveform is not stay fixed in the oscilloscope, even with the LEVEL volume changing.
Does anyone know which part of the oscilloscope the problem is from?
Regards Nb.
Hi!
Please, which part of waveform is not stay fixed - Horizontal or Vertical?
If the Vertical part, is it present with both Y channels?
Best Regards, Feri
0
Hi Ferenc.P
My problem is that the waveform is not stable...
I think it have trigger problem but i don't know which part is damaged...
The Trigger source switch is not working...
when i change trigger source nothing happening.
even i used LEVEL Volume to have a Stable wave form without moving but it made no difference.
thank you for replying and help.
and sorry for my bad english.
0
Hi "Anonymous"
The attached file show the trigger signal path from source to sweep generator input, but unfortunately You may need another Scope to check the signals presence. http://fileposta.hu/richlet/fd?id=Ee2509Eb29EfE18f3523F612C3Cd1a998d2fD9...
0
Thank you so much "Ferenc.P" for Replying and help.
0
Hi !
What kind of scope do you have for repair?
0
Instek GOS630 Oscilloscope
0